HV Report

HV Report (G-Q-R)

Extended filtered report with hourmeter, internal battery and two temperature sensors (OW0 and OW1). Ideal for machinery monitoring, equipment with backup battery and simultaneous temperature control.

This report combines multiple metrics useful for industrial machinery and special vehicles: operation time, backup battery status and temperature monitoring.


Generate report

GHVbbc[;@dd..dd]

See G Command for parameter details.

Query current position

QHV

Response

RHVAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSS%%%$$$$$$$$TUUUUVVXYYYYZZ

Field structure

FieldLengthDescription
AA2Report number (00-FF)
BBBBBB6Date (DDMMYY)
CCCCCC6Time (HHMMSS)
DDDDDDDD8Latitude (DDMMMMM)
EEEEEEEEE9Longitude (DDDMMMMM)
FFF3Speed (km/h)
GGG3Heading (degrees)
HH2IGN+IN inputs (hex)
II2XP outputs (hex)
JJJ3Vehicle battery voltage (tenths of V)
KKKKKKKK8Total odometer (meters, hex)
L1GPS Power: 0=Off, 1=On
M1GPS Fix Mode: 2=2D, 3=3D
NN2PDOP (decimal integer)
OO2Number of satellites
PPPP4Seconds since last pos. (hex)
Q1Modem Power: 0=Off, 1=On
R1GSM registration status
SS2CSQ signal level
%%%3Internal battery voltage (hundredths of V)
$$$$$$$$8Hourmeter (seconds, hex)
T1OW0 temperature sign (+ or -)
UUUU4OW0 temperature (hundredths C)
VV2OW0 reading age (sec)
X1OW1 temperature sign (+ or -)
YYYY4OW1 temperature (hundredths C)
ZZ2OW1 reading age (sec)

HV report specific fields

Internal battery (%%%)

FieldDescription
%%%Voltage in hundredths of Volt (e.g.: 420 = 4.20V)

The internal battery allows the device to continue operating during vehicle power outages, ideal for detecting disconnections.

Hourmeter ($$$$$$$$)

FieldDescription
$$$$$$$$Second counter in hexadecimal

Conversion:

  • To get hours: decimal_value / 3600
  • Example: 0000E10C = 57612 sec = 16.003 hours

To control the hourmeter, see HO Command.

Temperature OW0

FieldDescription
TSign: + (positive) or - (negative)
UUUUValue in hundredths of degree (e.g.: 2350 = 23.50C)
VVSeconds since last valid reading

Temperature OW1

FieldDescription
XSign: + (positive) or - (negative)
YYYYValue in hundredths of degree (e.g.: -0520 = -5.20C)
ZZSeconds since last valid reading

GSM registration status (R)

ValueDescription
0Not registered, no active search
1Registered, home network
2Not registered, searching for operator
3Registration denied
4Unknown
5Registered, roaming

CSQ signal level (SS)

ValueDescription
99No signal / Open
0-30Signal level (higher = better)

Report example

>RHV00291224153045-2778467-06425658045180810112700003A980130412000110115420000E10C+235005-052010;ID=974862;*5E<
FieldValueInterpretation
Report No.00Report 00
Date29122429/12/2024
Time15304515:30:45
Latitude-27784672778.467’S
Longitude-064256586425.658’W
Speed04545 km/h
Heading180180 (South)
Vehicle voltage12712.7V
Internal bat.4204.20V
Hourmeter0000E10C57,612 sec = 16.0 h
Temp OW0+235023.50C
Age OW0055 seconds
Temp OW1-0520-5.20C
Age OW11010 seconds

Hourmeter control

The hourmeter can be controlled through the HO Command:

// Start hourmeter >SHO01< // Stop hourmeter >SHO00< // Reset hourmeter >SHO02< // Query current value >QHO<

The hourmeter counts time while active, regardless of engine status. Configure it correctly according to your application.


Typical usage - Machinery

// Periodic report every 5 minutes with hourmeter >STD01E00300< >SRL01E;TRG=TD01+;ACC={GHV01L}< // Report when powering on equipment (start hourmeter) >SRL10E;TRG=IGN+;ACC={SHO01}{GHV10H}< // Report when powering off equipment (capture worked hours) >SRL11E;TRG=IGN-;ACC={GHV11H}{SHO00}< // Low internal battery alarm >SRL35E;TRG=BL00+;ACC={GHV35H}<

Comparison with other reports

ReportHourmeterInternal Bat.Temp OW0Temp OW1
CQNoNoNoNo
CVNoNoYesYes
HVYesYesYesYes

Compatibility

C3Legacy
ULLegacy
SPLegacy
C5Legacy
SP-IoT
SM-IoT
MT
ZE-IoT
Last updated