Skip to Content

BV Report

BV Report (G-Q-R)

Extended FILTERED + Internal Battery + OW0 Temperature + OW1 Temperature

See Extended Reports for common structure.


Generate report

GBVbbc[;@dd..dd]

Query

QBV

Response

RBVAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSS%%%TUUUUVVXYYYYZZ

BV specific fields

FieldDescriptionFormat
%%%Internal battery voltagehundredths of Volt
TOW0 temperature sign+ or -
UUUUOW0 temperaturehundredths of °C
VVOW0 reading ageseconds
XOW1 temperature sign+ or -
YYYYOW1 temperaturehundredths of °C
ZZOW1 reading ageseconds

Interpretation example

FieldValueMeaning
%%%420Battery = 4.20V
T+OW0 positive
UUUU2350OW0 = 23.50°C
VV02OW0 2 sec ago
X-OW1 negative
YYYY1825OW1 = -18.25°C
ZZ03OW1 3 sec ago

Ideal for cold chain applications with two measurement points (e.g.: freezer and refrigerated compartments).


Base fields included

See Extended Reports for complete description of fields AA-SS.


Compatibility

MTLegacy
C3Legacy
ULLegacy
SPLegacy
C5Legacy
ZE-IoT
SP-IoT
SM-IoT
Last updated