BV Report
BV Report (G-Q-R)
Extended FILTERED + Internal Battery + OW0 Temperature + OW1 Temperature
See Extended Reports for common structure.
Generate report
GBVbbc[;@dd..dd]Query
QBVResponse
RBVAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSS%%%TUUUUVVXYYYYZZBV specific fields
| Field | Description | Format |
|---|---|---|
| %%% | Internal battery voltage | hundredths of Volt |
| T | OW0 temperature sign | + or - |
| UUUU | OW0 temperature | hundredths of °C |
| VV | OW0 reading age | seconds |
| X | OW1 temperature sign | + or - |
| YYYY | OW1 temperature | hundredths of °C |
| ZZ | OW1 reading age | seconds |
Interpretation example
| Field | Value | Meaning |
|---|---|---|
| %%% | 420 | Battery = 4.20V |
| T | + | OW0 positive |
| UUUU | 2350 | OW0 = 23.50°C |
| VV | 02 | OW0 2 sec ago |
| X | - | OW1 negative |
| YYYY | 1825 | OW1 = -18.25°C |
| ZZ | 03 | OW1 3 sec ago |
Ideal for cold chain applications with two measurement points (e.g.: freezer and refrigerated compartments).
Base fields included
See Extended Reports for complete description of fields AA-SS.
Compatibility
MTLegacy
C3Legacy
ULLegacy
SPLegacy
C5Legacy
ZE-IoT
SP-IoT
SM-IoT
Last updated