IB Report
IB Command (G-Q-R)
Message that includes GPS data, input/output status, IButton ID and temperature. Identical structure to the GP Report with additional external hardware information.
Generate report
GIBbbc[;@dd..dd]See G Command for parameter details.
Query
QIBResponse
RIBAAAAAABBBBBBCCCCCCCCDDDDDDDDDEEEFFFGHHIIJJKK;LLLLLLLLLLLLLLLL;MNNNNOO[;#PPPP]Report fields
| Field | Description |
|---|---|
| AAAAAA | RTC Date (DDMMYY) |
| BBBBBB | RTC Time (HHMMSS) |
| CCCCCCCC | Latitude |
| DDDDDDDDD | Longitude |
| EEE | Speed (km/h) |
| FFF | Heading (degrees) |
| G | GPS Fix Mode (2=2D, 3=3D) |
| HH | Seconds since last valid position (hex) |
| II | Digital inputs status IGN+IN (hex) |
| JJ | Report number (00..FF) |
| KK | PDOP (decimal integer part) |
IB specific fields
| Field | Description |
|---|---|
| LLLLLLLLLLLLLLLL | Last registered DS1990 IButton ID |
| M | Temperature sign (+ or -) |
| NNNN | Temperature in hundredths of °C |
| OO | Seconds since last temperature calculation |
| PPPP | Message number (hex) |
IButton ID interpretation
The LLLLLLLLLLLLLLLL field contains the unique 8-byte ID of the DS1990 IButton device:
0100000012345678If no IButton is logged at the time of the report, the field is omitted to save data in transmission.
Temperature interpretation
| Example | Meaning |
|---|---|
| +2350 | +23.50°C |
| -0550 | -5.50°C |
| +0000 | 0.00°C |
The OO field indicates the age of the reading:
- 00: Current reading
- FF: More than 255 seconds without update
Important notes
Without GPS signal, date and time fields take values from the RTC (internal clock) instead of GPS data.
Compatibility
C3Legacy
ULLegacy
SPLegacy
C5Legacy
SP-IoT
SM-IoT
MT
ZE-IoT
Last updated