CT Report
CT Report (G-Q-R)
Extended FILTERED + IButton Read
See Extended Reports for common structure.
Generate report
GCTbbc[;@dd..dd]Query
QCTResponse
RCTAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSS;TTTTTTTTTTTTTTTTCT Specific Fields
| Field | Description |
|---|---|
| TTTTTTTTTTTTTTTT | Last IButton read (16 characters) |
The IButton field reports the last code read regardless of whether it belongs to the driver management list. If there is no reading, the field remains empty.
Report Example
>RCT00120520143022-2778467-0642565800007799001240000000013020700011;0100000012345678;#0100;ID=1234;*3A<Where 0100000012345678 is the ID of the DS1990 IButton read.
Base Fields Included
See Extended Reports for complete description of fields AA-SS.
Compatibility
C3Legacy
ULLegacy
SPLegacy
C5Legacy