Skip to Content

SC Report

SC Command (G-Q-R)

Reports the status of the Telemetric fuel flow sensor from Siid company connected to the device’s serial port.

Requires configuring the serial port to 4800 baud rate through CXTRM Command.


Generate report

GSCbbc

See G Command for parameter details.

Query

QSC

Response

RSCxxddmmaahhMMssabbbbbbbbccccddddddddddeeeefffggg[;#QQQQ]

Report fields

FieldDescription
xxReport number (00..FF)
ddDay
mmMonth
aaYear
hhHour
MMMinutes
ssSeconds

Flow meter data

FieldDescriptionFormat
aConnection status0=disconnected, 1=connected
bbbbbbbbTotal consumption1/10 Liters (bbbbbbb.b)
ccccConsumption flow rate1/10 L/h (ccc.c)
ddddddddddRunning timeSeconds (conditioned to IGN)
eeeeNumber of disconnectionsCounter
fffInlet temperature1/10 °C (-9.9 to 99.9)
gggReturn temperature1/10 °C (-9.9 to 99.9)
QQQQMessage numberHexadecimal

Flow meter frame

The Telemetric sensor sends this frame at 4800 baud:

SSCabbbbbbbbccccddddddddddeeeefffggg

Report example

>RSC03120312172844123324543022300345643812001341440;#0666;ID=1234;*2A<

Example interpretation

FieldValueMeaning
xx03Report #3
ddmmaa12031212/03/12
hhMMss17284417:28:44
a1Connected
bbbbbbbb233245432,332,454.3 liters consumed
cccc022322.3 L/h current flow
dddddddddd003456438134,564,381 sec running time
eeee20012001 disconnections
fff34134.1°C inlet
ggg44044.0°C return

Compatibility

C3Legacy
ULLegacy
C5Legacy
SP-IoT
SM-IoT
MT
SP
ZE-IoT
Last updated