Skip to Content

AD Report

AD Command (G-Q-R)

Reports the status of the device’s analog-to-digital converters: voltages on analog inputs, main battery, and backup battery.


Generate report

GADbbc[;@dd..dd]

See G Command for parameter details.

Query

QAD

Response

RADaaddmmyyhhMMssaaaabbbbccccddddeeeeffffgggghhhh[;#QQQQ]

Report fields

FieldDescription
aaReport number (00..FF)
ddDay
mmMonth
yyYear
hhHour
MMMinutes
ssSeconds

Analog values

FieldInputUnit
aaaaIN001/100 V
bbbbIN011/100 V
ccccIN021/100 V
ddddIN031/100 V
eeeeIN041/100 V
ffffIN051/100 V
ggggMain Battery1/100 V
hhhhBackup Battery1/100 V
QQQQMessage number (hex)-

Example

>RAD0002021201324512001200120012001200120012000420;#0666;ID=1234;*2A<

Example interpretation

FieldValueMeaning
aa00Report #0
ddmmyy02021202/02/12
hhMMss01324501:32:45
aaaa1200IN00 = 12.00V
bbbb1200IN01 = 12.00V
cccc1200IN02 = 12.00V
dddd1200IN03 = 12.00V
eeee1200IN04 = 12.00V
ffff1200IN05 = 12.00V
gggg1200Main Bat. = 12.00V
hhhh0420Backup Bat. = 4.20V

AD vs AE comparison

CharacteristicADAE
Value formatMagnitude onlySign + Magnitude
Typical useAbsolute valuesScaled values
ConfigurationDirectRequires CXAIN

Use AE report when you need scaled or signed values. Use AD for direct voltage readings.