✅ Installation Verification


🔍 Diagnostic Commands

TestCommandExpected Response
Device ID>QID<Your unique ID
APN Configuration>QCXAPN<Your configured APN
Cellular Status>QCEL<Carrier + signal
GPS Position>QGPS<Valid coordinates
Input Status>QIN<0/1 per input
Activate Output>SSSXP0111<OK + activates relay
CANBUS Status>QCAN<Vehicle data
iButton Reading>QOW<Key code
1-Wire Temperature>QOWT<Value in °C

✅ Verification Checklist

Power Supply

  • VCC connected to battery/fuses with 3A fuse
  • GND to solid ground point (chassis)
  • Power LED active

Communications

  • SIM card inserted correctly (no PIN)
  • GSM antenna connected
  • GPS antenna with sky view
  • >QCEL< returns carrier

Inputs/Outputs

  • IGN detects contact ON/OFF
  • Inputs respond to GND
  • Outputs activate relays correctly

Advanced Functions

  • CANBUS reads vehicle data (if applicable)
  • 1-Wire detects keys/temperature (if applicable)

🚨 Troubleshooting

ProblemPossible CauseSolution
Won’t turn onNo power supplyCheck VCC and fuse
No GSM signalAntenna or SIMCheck connections and data plan
No GPSLocation or antennaMove to area with sky view
Inputs not respondingIncorrect connectionVerify closure to GND
Outputs not activatingExcessive loadUse intermediate relay

For more commands, check the commands guide.

Last updated