Skip to Content

HR Report

Extended report filtered with hourmeter, internal battery and OW0 temperature.

See also: Extended Reports


Generate Report

>GHRbbc[;@dd..dd]<
ParameterDescription
bbTrigger number (00-FF)
cPriority: H, M, L
@dd..ddOptional destination

See G Command for more details.


Query

>QHR<

Response

>RHRAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSSTTT@@@@@@@@UVVVVWW<

Report Structure

FieldSizeDescription
AA2Report number (00-FF hex)
BBBBBB6Date DDMMYY
CCCCCC6Time HHMMSS
DDDDDDDD8Latitude (degrees × 100000)
EEEEEEEEE9Longitude (degrees × 100000)
FFF3Speed (km/h)
GGG3Heading (degrees)
HH2IGN+IN inputs status (hex)
II2XP outputs status (hex)
JJJ3Battery voltage (tenths of volt)
KKKKKKKK8Total odometer (meters, hex)
L1GPS power: 0=Off, 1=On
M1GPS fix: 2=2D, 3=3D
NN2PDOP (integer part)
OO2Number of satellites (decimal)
PPPP4Seconds since last fix (hex)
Q1Modem power: 0=Off, 1=On
R1GSM registration status*
SS2Signal level (CSQ)**
TTT3Internal battery (hundredths volt)
@@@@@@@@8Hourmeter (seconds, hex)
U1Temperature sign (+ or -)
VVVV4OW0 temperature (hundredths C)
WW2Seconds since last temp reading

* GSM Registration Status:

  • 0 = Not registered, not searching
  • 1 = Registered, home network
  • 2 = Not registered, searching
  • 3 = Registration denied
  • 4 = Unknown
  • 5 = Registered, roaming

** Signal Level (CSQ):

  • 99 = No signal
  • 0-30 = Signal level

Hourmeter

The @@@@@@@@ field contains a seconds counter in hexadecimal format.

To start, stop or reset the counter, use the HO Command.


See Also

Compatibility

C3Legacy
ULLegacy
SPLegacy
C5Legacy
SP-IoT
SM-IoT
MT
ZE-IoT
Last updated