Skip to Content

AE Report

AE Command (G-Q-R)

Reports the status of analog-to-digital converters with sign and magnitude of the read values. Each level depends on the attributes configured via CXAIN Command.


Generate report

GAEbbc[;@dd..dd]

See G Command for parameter details.

Query

QAE

Response

RAEaaddmmyyhhMMssnaaaaobbbbpccccqddddreeeesfffftgggguhhhh[;#QQQQ]

Report fields

FieldDescription
aaReport number (00..FF)
ddDay
mmMonth
yyYear
hhHour
MMMinutes
ssSeconds

Analog values with sign

SignValueInput
naaaaAIN00
obbbbAIN01
pccccAIN02
qddddAIN03
reeeeAIN04
sffffAIN05
tggggMain Battery
uhhhhBackup Battery
FieldDescription
QQQQMessage number (hex)

The sign can be + or -. Values are in 1/100 volt (hundredths).


Example

>RAE00020212013245+1200+1200+1200+1200+1200+1200+1200+0420;#0666;ID=1234;*2A<

Example interpretation

FieldSignValueMeaning
AIN00+1200+12.00V
AIN01+1200+12.00V
AIN02+1200+12.00V
AIN03+1200+12.00V
AIN04+1200+12.00V
AIN05+1200+12.00V
Main Bat+1200+12.00V
Backup Bat+0420+4.20V

Scale configuration

The reported values depend on the configuration of CXAIN:

  • Offset: Zero displacement
  • Gain: Scale factor
  • Unit: Allows representing temperature, pressure, etc.

Compatibility

MTLegacy
C3Legacy
ULLegacy
SPLegacy
C5Legacy
ZE-IoT
SP-IoT
SM-IoT
Last updated