CV Report

CV Report (G-Q-R)

Extended filtered report with data from two temperature sensors (OW0 and OW1). Ideal for cold chain applications, refrigerated transport, or environmental monitoring.

Temperature sensors use the 1-Wire (Dallas) protocol. To configure sensors, see Temperature Commands.


Generate report

GCVbbc[;@dd..dd]

See G Command for parameter details.

Query current position

QCV

Response

RCVAABBBBBBCCCCCCDDDDDDDDEEEEEEEEEFFFGGGHHIIJJJKKKKKKKKLMNNOOPPPPQRSSTUUUUVVXYYYYZZ

Field structure

FieldLengthDescription
AA2Report number (00-FF)
BBBBBB6Date (DDMMYY)
CCCCCC6Time (HHMMSS)
DDDDDDDD8Latitude (DDMMMMM)
EEEEEEEEE9Longitude (DDDMMMMM)
FFF3Speed (km/h)
GGG3Heading (degrees)
HH2IGN+IN inputs (hex)
II2XP outputs (hex)
JJJ3Battery voltage (tenths of V)
KKKKKKKK8Total odometer (meters, hex)
L1GPS Power: 0=Off, 1=On
M1GPS Fix Mode: 2=2D, 3=3D
NN2PDOP (decimal integer)
OO2Number of satellites
PPPP4Seconds since last pos. (hex)
Q1Modem Power: 0=Off, 1=On
R1GSM registration status
SS2CSQ signal level
T1OW0 temperature sign (+ or -)
UUUU4OW0 temperature (hundredths C)
VV2OW0 reading age (sec)
X1OW1 temperature sign (+ or -)
YYYY4OW1 temperature (hundredths C)
ZZ2OW1 reading age (sec)

Temperature fields

Temperature OW0

FieldDescription
TTemperature sign: + (positive) or - (negative)
UUUUValue in hundredths of degree Celsius (eg: 2350 = 23.50C)
VVSeconds elapsed since last valid reading

Temperature OW1

FieldDescription
XTemperature sign: + (positive) or - (negative)
YYYYValue in hundredths of degree Celsius (eg: -0520 = -5.20C)
ZZSeconds elapsed since last valid reading

If the age field (VV or ZZ) shows a high value, it indicates that the sensor may be disconnected or having communication problems.


GSM registration status (R)

ValueDescription
0Not registered, not searching
1Registered, home network
2Not registered, searching
3Registration denied
4Unknown
5Registered, roaming

CSQ signal level (SS)

ValueDescription
99No signal / Open
0-30Signal level (higher = better)

Report example

>RCV00291224153045-2778467-0642565804518081011270003A980130412000110115+235005-052010;ID=974862;*5E<
FieldValueInterpretation
OW0 Temp Sign+Positive
OW0 Temp Value235023.50C
OW0 Temp Age055 seconds
OW1 Temp Sign-Negative
OW1 Temp Value0520-5.20C
OW1 Temp Age1010 seconds

Typical usage - Cold chain

// Periodic report every 2 minutes for temperature monitoring >STD01E00120< >SRL01E;TRG=TD01+;ACC={GCV01L}< // Temperature out of range alarm (use with threshold rule) >SRL35E;TRG=TH00+;ACC={GCV35H}<

Version notes

Availability:

  • Firmware v1.10.07+ for: Spider, Ultralite, Minitrack, C3, C5
  • Firmware v1.00.00+ for: Spider IOT, Smart IOT

Compatibility

C3Legacy
ULLegacy
SPLegacy
C5Legacy
SP-IoT
SM-IoT
MT
ZE-IoT