🔌 Install the CP210x driver (Windows)
The Spider IoT talks to the PC over USB through a Silicon Labs CP210x chip. Windows needs its driver to create the COM port used by the Configurator and the Web Serial Terminal.
Video in Spanish: the Windows screens match the steps below.
🤔 Do I need to install it?
Connect the device to the PC and open Device Manager (Win + X → Device Manager).
| What you see | What it means |
|---|---|
| Under Ports (COM & LPT) you see Silicon Labs CP210x USB to UART Bridge (COM5) | ✅ The driver is already installed. Note the COM number and you’re done |
| Under Other devices you see CP2102 USB to UART Bridge Controller with a yellow triangle ⚠️ | ❌ The driver is missing. Follow this guide |
| Nothing new appears when you plug in the device | 🔍 Check the cable (see Troubleshooting below) |
📥 Step-by-step installation
Download the driver
Download the file from Downloads:
📥 CP210x_Universal_Windows_Driver.zip
Extract the ZIP
Right-click the file → Extract All… → Extract. You get a CP210x_Universal_Windows_Driver folder with:
silabser.inf
silabser.cat
x64\ x86\ arm\ arm64\This driver has no installer (there is no .exe to run). That’s why it is installed from Device Manager. It must also be extracted: if you only open the ZIP with a double click, Windows can’t find the driver.
Open Device Manager
With the device connected over USB, press Win + X and choose Device Manager.
Find the device with the yellow triangle ⚠️ under Other devices: CP2102 USB to UART Bridge Controller.
Update the driver
- Right-click CP2102 USB to UART Bridge Controller → Update driver
- Choose Browse my computer for drivers
- Click Browse… and select the folder you extracted
- Keep Include subfolders checked → Next
Windows installs the driver and shows Windows has successfully updated your drivers.
Check the COM port
The device moves to Ports (COM & LPT) as:
Silicon Labs CP210x USB to UART Bridge (COM5)Note the COM number: that’s the port you will pick in the Configurator or the terminal.
Quick alternative: inside the extracted folder, right-click silabser.inf → Install (on Windows 11, first Show more options). Then unplug and plug the device back in.
🔢 Change the COM port number
Some programs only list low ports (COM1 to COM9). If Windows assigned a high number:
- Right-click Silicon Labs CP210x USB to UART Bridge (COMxx) → Properties
- Port Settings tab → Advanced…
- Under COM Port Number pick a free one (for example
COM3) → OK - Unplug and plug the device back in
If Windows marks a port as (in use), it may be reserved by a device that is no longer connected. As long as no other device is using it right now, you can still pick it.
🛠️ Troubleshooting
Nothing appears when the device is plugged in
- Use a USB data cable: many charger cables only carry power
- Try another USB port on the PC, preferably a rear one (straight to the motherboard) and without a hub
- In Device Manager, Action menu → Scan for hardware changes
The device shows an error (Code 10 or other)
- Right-click → Uninstall device
- Check Attempt to remove the driver for this device (on Windows 10: Delete the driver software for this device) → Uninstall
- Unplug the device, plug it back in and repeat the step-by-step installation
The port appears but the program can’t connect
- Close any other program that has the port open (another terminal, another Configurator tab). A COM port can only be used by one program at a time
- Check the speed: 115200 for the Spider IoT
- Try
>QVR<: if the device replies with its version, communication works
💻 Other systems
- Linux: the
cp210xdriver ships with the kernel. The device shows up as/dev/ttyUSB0 - Driver with installer: Silicon Labs also publishes the CP210x VCP Windows package with an
.exeinstaller on its drivers page
📚 See also
- Downloads: drivers and tools
- Web Configurator: configure the device from the browser
- Web Serial Terminal: send commands over USB
- Getting Started